Reliable and high thermal conductive materials are made based on our own formulas and production techniques.
Test items | Conditions | Unit | ALC-1371 (120μm) |
ALC-1331 (80μm) |
Thermal Conductivity (LF) | A | W/m·K | 7 | 3 |
Breakdown Voltage DC | A | kV | >10 | >10 |
Breakdown Voltage AC | A | kV | 6 | 6 |
Peel Strength (35μm) | A | N/mm | 1.7 | 1.5 |
Flammability | UL94(A) | - | 94V-0 | 94V-0 |
Tracking Resistance | A (IEC method) |
V | 600 | 600 |
Tg | TMA | deg.C | 130 | 100 |
Young's Modulus | A | GPa | 40 | 21 |
Water Absorption | D-24/23 | % | 0.3 | 0.3 |
Chemical Resistance | 3%NeOH 40deg.C 3min |
- | OK | OK |
---|
* These are representative values, not specification
Test items | Conditions | CLC-5201 (175µm) |
|
Thermal Conductivity | w/m・K | Laser flash / 25°C | >12 |
---|---|---|---|
w/m・K | Laser flash / 175°C | >10 | |
Breakdown Voltage | kVrms | AC / 25℃ | >8 |
Volume Resistivity | Ω・cm | DC, 1 kV, 1 min / 25°C | 1E+16 |
Ω・cm | DC, 1 kV, 1 min/ 175°C | 1E+13 | |
Dielectric Constant | ― | 1MHz | 4.6 |
Tg | ℃ | TMA | >200 |
* The data table shown are representative values, not guaranteed values.